Industrial control Marantec-MFZ CS320
ATTENTION: This product is ONLY SUITABLE for PROFESSIONAL INSTALLERS!
Also suitable for Condor and Highline.
This industrial door control offers you the following benefits:
- All in 1 box
- Easy assembly and installation
- Reliable technology
- Suitable for motors with mechanical (MEC) and digital limit switches (AWG)
- Display for easy programming and error reading
Included as standard in this control
Control CS320 400V/3Ph
Integrated controls in the lid of the control box
Integrated LCD display
CEE plug
Manual
Control technical data
Type of control
CS320 400V / 3Ph
Connection voltage control
400V / 3Ph Vac
Power consumption (maximum)
2200W at 400V / 3Ph
Motor relay or variable speed drive?
Motor relay
Keypad on the control?
Yes
Traffic light connection?
Yes, via programmable outputs
Photocell connection?
Yes
Pass door sensor connection?
Yes
Connection pulse (Open/Stop/Down)?
Yes
Mechanical limit switches or electronic encoder?
Electronic Encoder (AWG)
Integrated radio receiver?
Optional: CS-funk (Multi-Bit) or Digital 991 (Bi-Linked)
Number of programmable radio stations
Multi-bit: unlimited or Bi-Linked: 100
Radio receiver frequency
To order as 433 or 868 MHz
Radio receiver encoding
Multi-bit or Bi-Linked
Rolling code?
Multi-Bit: No or Bi-Linked: Yes
Bidirectional communication?
No
Product properties
Manufacturer Warranty
12 months
Temperature range
-20ºC .. 50ºC
Additional features
Easy programming via LCD screen
Error message easy to read from screen
Replacement for AS130 controller:
The CS320 can serve as a replacement, but the following points are important:
[A] - The motor must not have a frequency inverter in the motor (or in the controller). The CS320 is NOT suitable for controlling these older frequency inverters and will cause problems.
[B] - The connections of the mechanical limit switches (pre-alarm and end position) must be checked thoroughly beforehand. In the past, multiple signals were often combined on a single connection on the AS130. The CS320 cannot do this. The signals must be connected separately to the CS320 controller. Ensure that each switch (MEC) can be connected separately to the printed circuit board with a wire.
[C] - If there are not enough wires in the wiring harness, a new cable between the motor and controller is necessary. We have these in stock in various lengths.
[D] - If your old system meets the requirements for replacement with a CS320, you must purchase the CS320 with a complete enclosure. The new CS320 circuit board will not fit in the old AS 130 controller enclosure.
{E] - The CS320 controller in its enclosure comes standard with a 3-phase (400V) connection cable. However, this controller can also be connected to a 1-phase (230V) power supply. During installation, carefully read the manual for connection and wiring instructions!
Replacement for:
Marantec control CS300
Marantec control CS310
MFZ control 82048
MFZ control CS300
MFZ control CS310